Display String
« on: July 17, 2004, 06:20:46 AM »
Reply with quote

Hi

I've been playing with the T100MD+ for sometime now and really enjoy using it. However, there are some problems I can not solve and would like to ask few questions:

1. I use VB to send host commands for writing integer and string variable to PLC,  now I want to display these setting on the LCD using TBasic. For example I use one input as increase button and another input as decrease button. By pressing increase, it will show numbers from 1 to 26 or from 26 to 1 depend on which button is pressed. At the same time A$ to Z$ should display the string content. I can use "RV$" command to show the string but I can not do it in TBasic. Do you have any similar command in TBasic?

2. Provide that I don't care about real time clock, can I connect battery to SRAM in order to save the content when the PLC is turn off?

3. Is it possible to upgrade the firmware to new version in order to use new commands?
Mine is version r44.

Gibus
Report to moderator   Logged
support
Global Moderator
*****

Posts: 3023





View Profile WWW E-Mail
Re:Display String
« Reply #1 on: July 20, 2004, 12:21:21 AM »
Reply with quote

1) I think you know that you can display the string variables on the LCD display by using the "SETLCD" command. If I guess it correctly you want to be able to use an index to select the string to display? The new command $$[n] allows you to select A$ (n=1) to Z$ (n=26) depending on value of n.

$$[n] command is only supported on firmware with revision r44 and above.

2) Connecting battery alone to the SRAM will not work since if the CPU does not find the presence of an MX-RTC it will reset the data upon power on reset. The only way is to keep power to the PLC ON all the time by using say an unterrupted power supply (UPS).

3) The firmware unfortunately is not user' upgradable. You can however purchase a new CPU from us to upgrade your PLC to the latest firmware revision (r47 at the moment).
Report to moderator   Logged

Email: support@triplc.com
Tel: 1-877-TRI-PLCS
gibus
Newbie
*

Posts: 2



I love YaBB 1G - SP1!

View Profile
Re:Display String
« Reply #2 on: July 22, 2004, 10:07:22 AM »
Reply with quote

Hi Support

I"ve got it worked now, many thanks for your help.
I also would like to know how many new TBasic commands you have so far, because in my TBasic manual, it does not have the command you mention.

gibus
Report to moderator   Logged
support
Global Moderator
*****

Posts: 3023





View Profile WWW E-Mail
Re:Display String
« Reply #3 on: July 23, 2004, 12:16:21 AM »
Reply with quote

Sign up to get the education version of trilogi program and you will receive an email to enter the webpage for downloading the educational trilogi (I know you don't need it since you have the production version already). You can then download the PDF version of Internet TRiLOGI reference manual (this one is for Windows). New command that are not supported on older firmware are mentioned in the manual.
Report to moderator   Logged

Email: support@triplc.com